Product Description
Factory Price XLPE Insulated Armoured Copper Power Cables
XLPE Insulated Armoured Cable:
Cross section: 10-500mm2
Standard: IEC60502
Operational performance
1.Installation temperature:≥0°C
2. Long-term permissible operation temperature≤90°C
3.Under the condition of short circuit (the max. continuing time should not exceeding 5 seconds) the max. operation temperature:250°C
4.Minimum bending radius:
Single-core cable: 20D, mm
Multicore cable: 15D, mm
Note: D means the actual outer diameter of cables
5. Suitable areas :
Direct burial in the ground and the capacity of bearing certain mechanical force, not proper in the pipeline.
6.Main electrical characteristics
6.Main electrical characteristics
Type | Cores | Nominal cross-sectional areas/mm2 | |
Copper conductor | Aluminum conductor | ||
VV VY --- VV22 VV23 | ---- VLV VLY VLV22 VLV23 | 1 | 1.5-800 2.5-800 10-800 |
VV VY --- VV22 VV23 --- VV32 VV33 | ---- VLV VLY --- VLV22 VLV23 VLV32 VLV33 | 2 | 1.5-300 2.5-300 4.0-300 10-300 |
VV VY ---- VV22 VV23 ---- VV32 VV33 | ---- VLV VLY ---- VLV22 VLV23 VLV32 VLV33 | 3 | 1.5-400 2.5-400 4.0-400 4.0-400 10-400 |
VV VY --- VV22 VV23 --- VV32 VV33 | ---- VLV VLY ---- VLV22 VLV23 VLV32 VLV33 | 4 | 1.5-400 2.5-400 4.0-400 4.0-400 10-400 |
VV VY --- VV22 VV23 --- VV32 VV33 | ---- VLV VLY ---- VLV22 VLV23 VLV32 VLV33 | 3+1 | 1.5-400 4.0-400 4.0-400 4.0-400 10-400 |
VV VY --- VV22 VV23 --- VV32 VV33 | ---- VLV VLY ---- VLV22 VLV23 VLV32 VLV33 | 5 | 1.5-400 2.5-400 4.0-400 4.0-400 10-400 |
VV VY --- VV22 VV23 --- VV32 VV33 | ---- VLV VLY ---- VLV22 VLV23 VLV32 VLV33 | 4+1 | 1.5-400 4.0-400 4.0-400 4.0-400 10-400 |
VV VY --- VV22 VV23 --- VV32 VV33 | ---- VLV VLY ---- VLV22 VLV23 VLV32 VLV33 | 3+2 | 1.5-400 4.0-400 4.0-400 4.0-400 10-400 |
Product Uses
Application range:
1. Rated voltage of cable U0/U(Um): 0.6/1(1.2)kV
2. The rated temperature of the cable conductor: The maximum assigned temperature of the cable conductor is 90°C.
3. Ambient temperature for laying: During the cable laying, the ambient temperature must be above 0°C, otherwise the
cable need be preheated.
4. The bend radius: The minimum bending diameter must be above the following standard.
Type |
Name |
Suitable areas | |
Copper-conductor |
AL-conductor | ||
YJV | YJLV | XLPE-insulated cable sheathed with PVC | Indoor, tunnel, cable channel |
YJY | YJLY | XLPE-insulated cable sheathed with polythene | |
YJV22 | YJLV22 | XLPE-insulated cable sheathed with PVC and armored with steel tape | Direct burial in the ground and the capacity of bearing certain mechanical force, not proper in the pipeline |
YJV23 | YJLV23 | XLPE-insulated cable sheathed with polythene and armored with steel tape | |
YJV32 | YJLV32 | XLPE-insulated cable sheathed with PVC and armored with thin steel wire | The bed of river and shallow sea, as the link line between the two platforms of oil and gas station in the water, the capacity of bearing tensile force. |
YJV33 | YJLV33 | XLPE-insulated cable sheathed with polythene and armored with thin steel wire | |
YJV42 | YJLV42 | XLPE-insulated cable sheathed with PVC and armored with thick steel wire | |
YJV43 | YJLV43 | XLPE-insulated cable sheathed with polythene and armored with thick steel wire |
Packaging & Shipping
In coils, wooden drums, steel drums or steel-wooden drums.
We could producing according to the customers' requirements.
Welcome your request for any quotations!