Conductor | Insulation | Electrical | Packing | |||
Sectional Area mm² | Conductor Construction NO.XΦmm | Diameter mm | Insulation Thickness mm | Outer Diameter mm | Max.Conductor Resistance DC 20℃ Ω/km | M/coil |
0.3 | 16x0.15 | 0.7 | 0.6 | 1.9 | 71.2 | 200 |
0.5 | 28x0.15 | 1 | 0.6 | 2.2 | 40.1 | 200 |
0.50 | 20x0.18 | 1 | 0.6 | 2.2 | 40.1 | 200 |
0.75 | 42x0.15 | 1.2 | 0.65 | 2.5 | 26.7 | 200 |
0.75 | 24x0.20 | 1.2 | 0.65 | 2.5 | 26.7 | 200 |
1 | 32x0.20 | 1.3 | 0.7 | 2.7 | 26.7 | 200 |
1.5 | 30x0.25 | 1.6 | 0.7 | 3 | 13.7 | 100 |
2.5 | 49x0.25 | 2.1 | 0.7 | 3.5 | 8.21 | 100 |
4 | 56x0.30 | 2.9 | 0.7 | 4.3 | 5.09 | 100 |
6 | 84x0.30 | 3.6 | 0.8 | 5.2 | 3.39 | 100 |
10 | 84x0.40 | 4.8 | 1 | 6.8 | 1.95 | 100 |
16 | 126x0.40 | 5.8 | 1.1 | 8 | 1.24 | 100 |
25 | 210x0.39 | 7.7 | 1.5 | 10.7 | 0.795 | 100 |
Features:
1.Maximum rated operating temperature:105°C;
2.Control line conductor maximum rated operating temperature:125°C;
3.Airway maximum rated operating temperature:125°C;
4.Excellent conductivity ,excellent flexibility ,aging crack resistance abrasion resistance,oil resistance, temperature corrosion resistance properties ,flame retardant, low smoke and toxic.
Application
1.Airway:125°C flame retarding crosslinked elastomers irradiation tube material;
2. Conductor :high purity oxygen free copper 99.99%;
3. Control line insulation layer:- soft conductor: high purity oxygen free copper 99.99%; Insulation: 125 ° C irradiation of low smoke zero halogen flame retardant insulation material;
4. Isolation layer:moisture absorption non-woven fabrics;
5. Outer sheath :105 ° C flame retarding crosslinked elastomers irradiation cable.